Measure Body Temperature

<< Click to Display Table of Contents >>

Navigation:  Temperature Measurement >

Measure Body Temperature

 

 

Steps:

1. Go to Configuration-->Temperature Measurement -->Body Thermography Configuration.

2. Select thermal channel.

 

 

 

3. Click Draw Area, then click the mouse on the black body in live view and save it.

4. Set the black body parameters.

Emissivity: Set the emissivity of black body.

 

UD1XXX~1_img4Note

Refer to the emissivity table for reference in the manual or online.

 

 

Distance: The straight-line distance between the black body and the device.

 

Temperature: Enter the temperature of the black body.

 

UD1XXX~1_img4Note

If there is no black body in the scene, skip step 3 and 4 .

 

 

5. Set Environmental Temperature Mode. Auto and Manual are selectable. In auto mode, the device detects environment temperature automatically. In manual mode, you should enter environment temperature manually.

6. Set the body temperature compensation parameters if you need to detect human body

temperature instead of shell temperature.

i.        Enable body temperature compensation function. ii.        Select the compensation type.

iii.In auto mode, the device calculates compensation value automatically. If the detected body temperature is still inaccuracy, you can set Manual Calibration value.

 

iv.In manual mode, you should enter Manual Calibration value, and corresponding compensation value displays in Compensation Value field.

7. Click Save.

8. Set the arming schedule and linkage methods. For the information about arming schedule settings, see Set Arming Schedule. For the information about linkage methods, see Linkage Method Settings.