Trigger Alarm Output

<< Click to Display Table of Contents >>

Navigation:  Arming Schedule and Alarm Linkage > Linkage Method Settings >

Trigger Alarm Output

 

If the device has been connected to an alarm output device, and the alarm output No. has been configured, the device sends alarm information to the connected alarm output device when an alarm is triggered.

 

Steps

1. Go to Configuration Event Basic Event Alarm Output.

2. Set alarm output parameters.

 

Automatic Alarm        For the information about the configuration, see Automatic Alarm.

 

Manual Alarm        For the information about the configuration, see Manual Alarm.

 

3.   Click Save.

 

 

 

Manual Alarm

 

You can trigger an alarm output manually.

 

Steps

1. Set the manual alarm parameters.

 

Alarm Output No.

Select the alarm output No. according to the alarm interface connected to the external alarm device.

 

Alarm Name

Custom a name for the alarm output.

 

Delay

Select Manual.

2. Click Manual Alarm to enable manual alarm output.

3. Optional: Click Clear Alarm to disable manual alarm output.

 

 

Automatic Alarm

 

Set the automatic alarm parameters, then the device triggers an alarm output automatically in the set arming schedule.

 

Steps

1. Set automatic alarm parameters.

 

Alarm Output No.

Select the alarm output No. according to the alarm interface connected to the external alarm device.

 

Alarm Name

Custom a name for the alarm output.

 

Delay

It refers to the time duration that the alarm output remains after an alarm occurs.

2. Set the alarming schedule. For the information about the settings, see Set Arming Schedule.

3. Click Copy to… to copy the parameters to other alarm output channels.

4. Click Save.