Example - Multiple Pairs

<< Click to Display Table of Contents >>

Navigation:  Pairing >

Example - Multiple Pairs

Pairing on channel 100 and 104

 

1. Power one pair of IPmitters, and leave to boot up for at least 3 mins. During boot up they will display a rotating segment [    _i]

 

2. On one IPmitter (client), press the F (function) button and "H" will flash [H 100] . Press the S (setting) button to change to [C 100].

 

3. The whole display will flash to indicate the settings have been saved, it will reboot (can take up to 3 mins) then the display will show [C036].

 

4. Now press the RST (reset) button for 1 second on both IPmitters [H 100] [C036].

 

The display will change to a P with a rotating segment whilst pairing [P  __]. Pairing can take up to 5 minutes.

 

The display will show P and a value once paired [P0 10] [P0 12].

 

5. Down-power the paired units and then boot up the next pair.

 

6. On one IPmitter (client), press the F (function) button and "H" will flash [H 100]. Press the S (setting) button to change to [C 100].

 

7. The whole display will flash to indicate the settings have been saved, it will reboot (can take up to 3 mins) then the display will show [C036].

 

8. On the Host, press the F (function) button two times. Press the S (setting) button to change to [H 104].

 

9. Now press the RST (reset) button for 1 second on both IPmitters [H 104] [C036].

 

The display will change to a P with a rotating segment whilst pairing [P  __]. Pairing can take up to 5 minutes.

 

The display will show P and a value once paired [P0 10] [P0 12].

 

10. Power the first pair of IPmitters back up and check to ensure the two pairs work correctly.