<< Click to Display Table of Contents >> Navigation: »No topics above this level« Pairing |
Available Channels – Available channels 34-64, 100-140 (In multiples of 4)
The IPmitters are sent out as default on H (Host).
One IPmitter needs to be set to H (Host) and the other to C (Client).
Ensure the IPmitters are paired up before installing in position.
The units can be down-powered and then installed in position once paired.
IMPORTANT :
Keep both IPmitters at least 2m apart during pairing, if the they are too close they will "de-sense" and not pair.
If they are very close then point them away from each other during pairing to ensure they do not "de-sense".
Do not attempt to pair both IPmitters connected to the same PoE switch, they will detect a network loop and not pair.
If pairing is attempted with both IPmitters connected to the same PoE switch then default both units (press and hold rst button for at least 10 seconds).
Note:
Super WDS mode is not used in the IPMIT304 models, as they now use repeater and access point modes.
The Client is set to repeater mode and the Host is set to access point mode.
When pairing an older model IPMIT300 with a new model IPMIT304, then the IPMIT300 is required to be set manually in the web interface to either access point mode or repeater mode (depending on if being used as a client or a host).