Park Action (Default Postion)

<< Click to Display Table of Contents >>

Navigation:  Configuration & Operation >

Park Action (Default Postion)

 

Park action (default position) will have the PTZ go back to a preset position, tour or pattern after no manual control after a specified time period has ended.

 

Power action can also be configured to have the PTZ do the same when the PTZ boots up, after a power loss.

 

Set in PTZ OSD Menu

 

1.Enter the PTZ controls.
 

2.Position the camera at the start the record pattern sequence.
 

3.Select the <GO TO/ Call preset > Preset 95 .
preset-95
 

4.The Main Menu will then display on the screen. Note that the "&" character needs to be moved into editing mode by moving the right arrow and left to exit.
Go down to System Setting > then press IRIS + / right.
PTZ-Menu
 

5.Go to Movement Control menu and then press IRIS + / right.
AB-1
 

 

6.Set the below;
Park Act Time from NO to 1-255 Seconds.
Park Act from NO to Preset 1-8 / Patrol 1-8 / Pattern 1-8 / Auto Scan / AB Scan.
Power Act from NO to Preset 1-8 / Patrol 1-8 / Pattern 1-8 / Auto Scan / AB Scan.
Park-Action - Copy
 

7.Press the IRIS- to exit out of menu.