Set Normal Mode

<< Click to Display Table of Contents >>

Navigation:  Temperature Measurement > Automatic Thermography >

Set Normal Mode

 

This function is used to measure the temperature of the whole scene and alarm.

 

Steps

1. Go to Configuration Temperature Measurement Basic Settings, and check Enable

Temperature Measurement.

2. Refer to Set Thermography Parameters to set the parameters.

3. Go to Configuration Temperature Measurement Advanced Settings, and select Normal.

4. Configure the parameters of normal mode.

 

Emissivity

Set the emissivity of your target. The emissivity of each object is different.

 

Distance

The distance between the target and the device.

 

Pre-Alarm Threshold

When the temperature of target exceeds the pre-alarm threshold, and this status keeps more than Filtering Time, it triggers pre-alarm.

 

Alarm Threshold

When the temperature of target exceeds the alarm threshold, and this status keeps more than Filtering Time, it triggers alarm.

 

Pre-Alarm Output and Alarm Output

Check Pre-Alarm Output and Alarm Output to link the pre-alarm or alarm with the connected alarm device.

5. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for setting linkage method.

6. Click Save.

The maximum and minimum temperature will be displayed on the live view.

 

UD1XXX~1_img4Note

Go to Image VCA Rules Display to adjust the fonts size and the temperature colour of normal, alarm and pre-alarm.